A passive multibody model of the adult human skeleton for visualising how intentional movement propagates through the body.

44 segmentsrigid bodies, CT-derived geometry
118 jointsthree rotational degrees of freedom per spinal level
15 / 15validation checks within published ranges
The model represents a single reference body and contains no muscles. It is intended for visualisation and teaching; it does not describe any individual and is not a clinical or diagnostic tool.

1. Overview

The model is a rigid multibody system simulated in MuJoCo [1] with a 1 ms time step and implicit integration of joint damping. It comprises 44 rigid segments: the pelvis (free-floating), 24 vertebrae and the skull, a pair of ribs attached to each thoracic vertebra, the shoulder girdle, upper limbs, lower limbs and feet. Each intervertebral joint is represented by three orthogonal hinges (flexion–extension, lateral bending, axial rotation). Muscles are not modelled; joint behaviour arises from passive tissue properties, joint limits and a minimal postural tone.

2. Model description

2.1 Geometry and inertial properties

Bone geometry is taken from BodyParts3D [2], a CT-derived whole-body model of an adult male. Segment lengths are derived from joint landmarks on that skeleton (intervertebral disc centroids, femoral head, tibial plateau, talus, glenohumeral and elbow centres) and scaled to a stature of 1.76 m. Total mass is 70 kg, distributed across segments according to de Leva [3].

2.2 Joint kinematics

Intervertebral ranges of motion follow the representative values of White and Panjabi [4], with thoracic axial rotation (±5° per level, T1–T9) after the in-vitro data of Wilke et al. [5] and L5–S1 axial rotation (±2°) after the in-vivo MRI data of Fujii et al. [6]. The rest configuration includes a sacral slope of 35°, lumbar lordosis of 40°, thoracic kyphosis of 32° and cervical lordosis of 30°. The knee permits flexion and axial tibial rotation; the talocrural and subtalar axes are inclined after Inman [11].

2.3 Passive joint properties

The passive moment resisting a displacement d from rest at each spinal joint is

M(d) = c · (ea d / r − 1),

where r is the range of that level on the side of displacement. The coefficient c is shared by all levels of a region, so that levels in series yield in proportion to their range. For the lumbar spine, a and the whole-region stiffness at rest were fitted to the quartile stiffnesses of the in-vivo meta-analysis of Watt et al. [7]: flexion a = 2.60, 0.243 N·m/°; lateral bending a = 3.67, 0.198 N·m/°; axial rotation a = 2.33, 0.140 N·m/°. Thoracic levels are assumed to share the lumbar coefficients. Cervical coefficients reproduce the mean axial rotation stiffness of 0.07 N·m/° reported by De Boe et al. [8]. Hip rotational stiffness is 8 N·m/rad, within the range reported in vivo [9, 10]. Remaining limb joints combine a linear stiffness with exponential stiffening over the second half of their range.

2.4 Postural tone

No starting position is maintained by passive tissue alone. Each position therefore adds a joint stiffness toward its posture, set to the smallest value that maintains it (e.g. 8 N·m/rad of hip tone in crook lying; 3000 N·m/rad per spinal level in upright sitting). On hands and knees the trunk hangs between the arms and thighs and needs far less: 300 N·m/rad per level, with which the lumbar spine extends about 10° beyond its standing curve (19° with none) and a pelvic tilt still spreads up the spine; the arms, shoulder girdle and hips carry 300 N·m/rad each. Positions that stand on the hands settle without the brief low-friction phase used for lying, which would let the limbs swing like the legs of a folding table. During intentional movement the reference of this tone follows the intended joint angle.

2.5 Contact

Soft tissue is represented by compliant ellipsoidal and spherical contact surfaces (compliance of approximately 2 cm) over the posterior pelvis, the paravertebral regions, the lateral thorax, the scapulae, the occiput, the limbs and the soles. Contact uses elliptic friction cones with a friction coefficient of 0.9 (1.2 for the soles) and a no-slip solver. The environment comprises a floor and, where required, a chair or a pillow.

2.6 Movement generation

Intentional movement is prescribed on a small number of points of the body, through virtual springs attached to moving targets, or on joint angles, through proportional control. All other degrees of freedom are unactuated, so the response of the rest of the body is determined by gravity, contact and passive joint properties.

3. Parameter sources

ParameterSourceBasis
Bone geometry, segment lengthsBodyParts3D [2]measured
Segment massesde Leva [3]measured
Intervertebral ranges of motionWhite & Panjabi [4]; Wilke et al. [5]; Fujii et al. [6]measured
Lumbar passive stiffnessWatt et al. [7]measured
Cervical passive stiffnessDe Boe et al. [8] (axial rotation)measured
Hip passive stiffnessLeite et al. [9]; Manual Therapy study [10] (rotation)measured
Ankle and subtalar axesInman [11]measured
Thoracic passive stiffnesslumbar coefficientsassumed
Knee, ankle, shoulder and upper-limb tissue-assumed
Soft-tissue contact, friction, damping-assumed
Postural toneminimal value maintaining each postureassumed

4. Validation

Model behaviour is compared with in-vivo measurements after every change to the model. Static checks compute moment–angle relations of joint chains under uniform moment; the trunk-rotation check computes the axial rotation of each lumbar level for a 45° rotation of the trunk relative to a fixed pelvis. Because the reference studies differ in subjects, posture and method, agreement indicates consistency of individual components with published data, not validation of the model as a whole.

QuantityPublishedModel
Loading…

5. Limitations

References

  1. Todorov E, Erez T, Tassa Y. MuJoCo: A physics engine for model-based control. IEEE/RSJ Int Conf Intelligent Robots and Systems (IROS), 2012.
  2. Mitsuhashi N, Fujieda K, Tamura T, Kawamoto S, Takagi T, Okubo K. BodyParts3D: 3D structure database for anatomical concepts. Nucleic Acids Res 2009;37:D782–5. PubMed. Meshes © DBCLS, CC BY 4.0.
  3. de Leva P. Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters. J Biomech 1996;29:1223–30.
  4. White AA, Panjabi MM. Clinical Biomechanics of the Spine, 2nd ed. Philadelphia: Lippincott, 1990.
  5. Wilke H-J, Herkommer A, Werner K, Liebsch C. In vitro analysis of the segmental flexibility of the thoracic spine. PLoS ONE 2017;12:e0177823. doi:10.1371/journal.pone.0177823
  6. Fujii R, Sakaura H, Mukai Y, et al. Kinematics of the lumbar spine in trunk rotation: in vivo three-dimensional analysis using magnetic resonance imaging. Eur Spine J 2007;16:1867–74. PubMed
  7. Watt, Callaway, Williams. In vivo through-range passive stiffness of the lumbar spine: a meta-analysis of measurements and methods. Med Biol Eng Comput 2022;60:2133–57. doi:10.1007/s11517-022-02609-w
  8. De Boe et al. Passive axial rotation stiffness of the cervical spine in asymptomatic adults. Mains Libres 2016. PDF
  9. Leite et al. Relationship between joint passive stiffness and hip lateral rotator concentric torque. Rev Bras Fisioter 2012;16(5). PubMed
  10. Validity and reliability of clinical tests for assessing hip passive stiffness. Manual Therapy. ScienceDirect
  11. Inman VT. The Joints of the Ankle. Baltimore: Williams & Wilkins, 1976.